消毒机

  • 网络Disinfection machine;pasteurizer;OZ-BL-A
消毒机消毒机
  1. 基于ADAMS的一种可伸缩多用途手臂消毒机的运动分析

    Kinematics of an automatic multi-purpose arm - disinfection machine based on ADAMS

  2. DF型空气消毒机的效果观察与分析

    Effect observation and analysis of disinfecting by DF type air sterilizing machine

  3. TiO2紫外复合消毒机在零污水排放的工厂化养殖系统中杀菌效果研究

    Sterilization of TiO_2 UV Sterilizer in a Zero Discharge Integrated Recirculating Industrialized Aquaculture System

  4. 紫外线灯与动态消毒机配合使用,可使车内工作中空气自然菌数维持在符合III类环境卫生标准。

    Combined use of ultraviolet lamp and the dynamic disinfector for disinfection of occupied car could still keep the natural bacterial count in air of the car conforming to class - ⅲ environmental sanitation standard .

  5. 床旁呼出气体消毒机主要针对SARS等烈性呼吸道传染病病人呼出的有害气体进行消毒。

    Sterilizing machine of expiration beside the sickbed is mainly directed against harmful gases exhaled from the patients who were attacked by the deadly infectious disease of respiratory tract , such as SARS etc.

  6. 动态空气消毒机在人员流动的采血环境消毒1h,空气中自然菌数<500CFU/m3。

    The bacterial colony forming unit of air in blood-collecting environment was less than 500CFU / m3 after the air had been disinfected by dynamic disinfector in occupied condition for 1 hour .

  7. 用多功能循环风消毒机连续运行60min,可使空气中自然菌消亡率达到96.3%。

    Operation of multifunctional circulating wind disinfector for 60 min could cause eradicating 96.3 % of natural bacteria in air .

  8. 结果,被服消毒机启动连续作用60min,对布片上枯草杆菌黑色变种繁殖体平均杀灭率为99.99%。

    Results : Continuous operation of the clothing disinfection machine for 60 min killed 99.99 % of vegetative form of Bacillus subtilis var. niger on cloth strip .

  9. 用该等离子体消毒机对染菌载体上白色念珠菌作用120s杀灭率为99.98%,作用180s,杀灭率为100%;

    Disinfection with this plasma disinfector for 120 s killed 99.98 % of Candida albicans on carrier and disinfection for 180 s killed 100 % .

  10. 结论,被服消毒机,采用一袋一床进行密闭消毒60min,密扎30min,消毒效果较理想。

    Conclusion : Closed disinfection of one bed clothing in one bag for 60 min in the clothing disinfection machine and tightly ligating the bag for 30 min gave ideal disinfection efficacy .

  11. XD-1型医疗仪器管路消毒机杀菌因子为臭氧,为观察其杀菌效果,采用载体定量杀菌试验进行了观察。

    The germicidal agent of XD-1-Type Medical Instrument Tube Disinfector is ozone . In order to observe its germicidal efficacy , carrier quantitative germicidal test was used to carry out observation .

  12. 结果直接曝光式大气压辉光放电等离子体消毒机对染菌载体(玻璃片)上的金黄色葡萄球菌和大肠杆菌作用45s,平均杀灭率达99.99%,作用60s杀灭率可达100%。

    Results Disinfection with the direct-type atmospheric glow discharge plasma disinfector for 45 s killed 99.99 % in average of Staphylococcus aureus and Escherichia coli on carrier ( glass slide ) and disinfection for 60 s killed 100 % .

  13. KGD-1800型高电压空气消毒机由进风机、过滤器、离心风机、多机线棒蜂巢静电场、负离子发生器与浸渍型活性炭吸附器等组成。

    KGD-1800-Type High-voltage Air Disinfector is composed of draft fan , air filter , air centrifuge , honeycomb electrostatic field , anion generator and activated carbon adsorber . Its efficacy in removing bacteria and purifying air was observed experimentally .

  14. 结果,该消毒机开机作用60min,对气雾室空气中污染的金黄色葡萄球菌平均杀灭率可达99.91%;作用90min,对60m~3大小的无人隔离室空气中的自然菌消亡率可达90.06%。

    The results showed that operation of the disinfector for 60 rain killed 99.91 % in average of Staphylococcus aureus in air of aerosol chamber and operation for 90 min could cause 90.06 % decay rate of natural bacteria in air of non-occupied isolation room .

  15. 手术室应用静电吸附型空气消毒机的效果观察

    Observation of effects of air sterilizer used in the operation room

  16. 床单位空气两用消毒机消毒效果试验观察

    Experimental observation on disinfection efficacy of bed unit-air dual purpose disinfector

  17. 塑料医疗废弃物毁形消毒机可行性分析

    Feasibility Analysis on Disinfector that Destroys Forms of Plastic Medical Wastes

  18. 呼吸机管路;清洗消毒机;性能分析;

    Ventilator-pipe ; Cleansing and disinfection machines ; Performance analysis ;

  19. 臭氧被服消毒机杀菌效果的影响因素研究

    Influence Factors Acted on Germicidal Efficacy of a Bed Unit Ozone Sterilizer

  20. 医用毁形消毒机设计

    Design of crushing plant with disinfectant function used in medicine

  21. 采血车上应用动态消毒机的效果评价

    Evaluation of efficacy of dynamic disinfector used on blood-collecting car

  22. 静电吸附型空气消毒机消毒效果优于传统紫外线消毒法。

    The disinfectant effect of static electricity absorptive air sterilizer was better .

  23. 连续式空气消毒机应用于手术室的效果观察

    Study the effect of the continuous air disinfector on operation-room

  24. 高电压空气消毒机对室内空气洁净效果的研究

    Study on efficacy of high voltage air disinfector in purifying indoor air

  25. 目的了解电解式臭氧空气净化消毒机消毒性能。

    Objective To know the disinfection performance of electrolysis-type ozone air-purifying disinfector .

  26. 结论三氧消毒机空气消毒效果优于紫外线。

    Conclusion Ozonizer disinfection is more effective than ultraviolet ray .

  27. 装置是紫外线、三氧消毒机的更新换代产品。臭氧(英文)

    It is an upgrading product of ultraviolet radiation and ozone sterilizing machine .

  28. 自动空气杀菌消毒机设计与控制实现

    The Design and Control Process of Air Disinfection Auto-Device

  29. 智能型纸币消毒机控制系统的设计与实现

    Design and Implementation of Control System in Banknote Disinfectors

  30. 床单位臭氧消毒机消毒效果研究

    Study on germicidal efficacy of bed unit ozone sterilizer