臭氧消毒

  • 网络ozonation;ozone;Ozone disinfection
臭氧消毒臭氧消毒
  1. 本文研究了污水回用的臭氧消毒工艺,包括臭氧在水中的衰减、二级出水的需臭氧量、接触时间和臭氧投量与微生物灭活之间的关系,并提出相应的数学模型。

    In this paper , a research work on ozonation of secondary effluent including decay of ozone in secondary effluent and distilled water , ozone demand of secondary effluent , the relationship between bacteria inactivation rate and ozone dosage , contact time is illustrated .

  2. 我国饮用水消毒的方法主要有液氯消毒、二氧化氯消毒、紫外线C穿透照射消毒和臭氧消毒等。

    The method that our drinking water disinfect mainly has the liquid chlorine to disinfect , two oxidize chlorine disinfection , the ultraviolet ray C to wear to project light upon to disinfect deeply and ozone to disinfect etc.

  3. CX臭氧消毒箱及其应用研究

    CX ozone desinfection chest and its application

  4. 废水经臭氧消毒14h后对细菌的杀灭率达到92.7%,对弧菌的杀灭率在5h的时候便达到了100%,氧化还原电位提高了约18.6%。

    The germicidal rate of bacteria reached 92.7 % and of vibrio 100 % after 5 h.

  5. 目的比较NYO33000S床单位臭氧消毒器和ZXCII型紫外线消毒车对床单位的消毒效果。

    Objective To compare the sterilization effects between type NYO 3 3000S bed unit ozone sterilizer and type ZXC II ultraviolet sterilizing vehicle .

  6. 未用臭氧消毒处理的冬枣在相同包装和储存条件下,只能储存40d,之后即出现冬枣腐烂。

    The winter jujube in same packing and storing condition and not treated with ozone disinfection could only be stored for 40 days and putrefied thereafter .

  7. 该方法比较适于检测经氯剂消毒或臭氧消毒的饮用水中的大肠杆菌,检测结果与常规滤膜培养法有较好的一致性,且分析时间短(4~5h)、反应灵敏。

    The method is more suitable for detecting the coliform in chlorine and ozone disinfected drinking water , and is in good agreement with the conventional membrane filter method . It is characterized by short period of analysis ( 4-5 h ) and more sensitive detection .

  8. 饮水机臭氧消毒器杀菌效果观察

    Observation on Bactericidal Efficacy of Ozone Disinfector on Drinking Water Dispenser

  9. 大型压力蒸汽与臭氧消毒床垫的效果比较

    The comparison between the sterile effects of vacuum pressure and ozone

  10. 臭氧消毒方式在医药行业生产洁净区(室)中的应用

    Applications of O_3 Sterilization in the Clean Rooms of Pharmaceutical Factory

  11. 床单位臭氧消毒器用于污染被服消毒的效果评价

    Evaluation on effect of ozone disinfector applied in bed unit clothes disinfection

  12. 臭氧消毒冬枣预防腐烂的试验研究

    Experimental study on prevention of putrefaction of winter jujube by ozone disinfection

  13. 生物氧化结合臭氧消毒生活饮用水净化处理的效果

    Effect of bio - oxidizing combined with ozone to purify drinkable water

  14. 臭氧消毒水对创伤愈合及抗感染疗效观察

    Effects of Ozone Solution on the Healing and Anti-infection of Traumatic Wound

  15. 臭氧消毒医院污水的应用

    Use of ozone for disinfection of sewage in hospital

  16. 使用臭氧消毒器对室内空气的污染

    The Pollution of Ozone Disinfection Apparatus on Indoor Air

  17. 鼓泡接触器中的臭氧消毒过程数学模型

    The mathematical models of ozone disinfection in bubbling contactor

  18. 床单位臭氧消毒机消毒效果研究

    Study on germicidal efficacy of bed unit ozone sterilizer

  19. 目的评价病床单位臭氧消毒的效果。

    Objective To evaluate the effect of ozone used to sterilize sickbed unit .

  20. 在烧伤病房中使用臭氧消毒空气的效果观察

    Observation on the efficacy of ozone for disinfection of air on burn ward

  21. 本实用新型提供的是养鸡舍臭氧消毒净化器。

    The utility model relates to an ozone disinfection purifier for a henhouse .

  22. 臭氧消毒技术原理及其应用前景分析

    Principle of Ozone Disinfecting Technology and Its Application Prospect

  23. 目的评价饮水机臭氧消毒器杀菌效果。

    Objective To assess the bactericidal efficacy of ozone disinfector on drinking water dispenser .

  24. 结合实际生产运行,建立了臭氧消毒系统的费用估算模型。

    The cost estimation model has been established on the basis of practical operation .

  25. 泡沫分离&臭氧消毒装置的水处理效果研究

    Water Treatment Effects of Foam-Separation and Ozonic-Sterilization Device

  26. 臭氧消毒与臭氧消毒机的研制

    Development of ozone disinfection and ozone disinfectant machine

  27. 臭氧消毒中溴酸盐的形成、检测与控制

    Formation , Detection and Control of Bromate in the Ozone Disinfection of Drinking Water

  28. 其中以蒸汽消毒效果最佳,合格率为85.75%,臭氧消毒柜效果最差,合格率仅为48.25%。

    The ozone disinfection effect was worst , the qualified rate was 48.25 % .

  29. 欧洲在一百多年前即有用臭氧消毒饮水者。

    Europe in more than 100 years ago that useful ozone disinfection of drinking water .

  30. 床单位臭氧消毒器对医院被服类物品消毒效果观察

    Observation on efficacy of bed unit ozone disinfector in disinfection of hospital bedding and clothing