支柱绝缘子

  • 网络post insulator
支柱绝缘子支柱绝缘子
  1. 220kV支柱绝缘子断裂原因分析及对策

    Analysis and Countermeasures of Fracture of 220 kV Post Insulator

  2. 高压瓷瓶支柱绝缘子有限元应力分析及安全性评定

    Finite Element Stress Analysis and Security Assessment of HV Porcelain Post Insulator

  3. 高压GIS开关设备共箱母线内支柱绝缘子的受力分析

    The Mechanical Analysis on Post Insulator of Common Enclosure Busbar of High Voltage Switchgear of GIS

  4. 在I、II级污秽等级的站址环境下,瓷质外绝缘单个支柱绝缘子、套管以及其他瓷质类设备难以满足户外要求;

    Under I or II class contamination conditions of station site , ceramic post insulator , sleeve and other ceramic devices are difficult to meet outdoor usage requirements .

  5. 750KVGIS支柱绝缘子故障分析

    Fault Analysis of the 750 kV GIS Supporting Insulators

  6. 涂覆RTV的电瓷支柱绝缘子在±800kV特高压换流站的应用研究

    Application Study of RTV-Coated Electric Porcelain Post Insulator in ± 800 kV UHV Converter Station

  7. 高海拔地区±800kV复合支柱绝缘子直流污闪特性

    DC Flashover Performance of ± 800 kV Composite Post Insulator in High Altitude Area

  8. 110kV支柱绝缘子交流覆冰(雪)电气特性

    AC Electric Characteristics of 110 kV Post Insulators Covered with Ice or Snow

  9. 35~220kV系列重污棒型支柱绝缘子的试验研究

    The Tests and Studies of 35 ~ 220kV Cylindrical Insulators Series Used in Heavy Pollution Areas

  10. 关于500kV升压站支柱绝缘子污闪防治的探讨

    Some Discussion on Prevention and Control of Pollution Flashover Caused by Post Insulator in 500 kV Step-up Substation

  11. 研究结果表明,对于支柱绝缘子,其冲击闪络电压与湿度之间的关系基本符合现行IEC标准。但对于套管,其冲击闪络电压与湿度之间的关系与现行IEC标准完全相反,大致成镜像关系。

    The results show that the relationship between impulse flashover voltage and humidity is coincided with the current IEC standard for support insulators , however a just opposite tendency was found when impulse flashover occurred along bushing surfaces .

  12. 1000kV变电站用支柱绝缘子和套管存在的问题及解决思路

    The Existent Problems and Solutions of Post Insulator and Bushing for 1000 kV AC Substation

  13. 在济南、潍坊两供电公司进行了现场实测,同时深入研究了RTV涂层对超声探伤影响的程度,并从经过超声探伤的试品中抽取部分支柱绝缘子进行机械强度试验。

    Ultrasonic crack detection test was carried out both in Jinan and Weifang electrical power company , effect of RTV coating on Ultrasonic crack detection was studied at the same time , several post porcelain insulators were selected to do mechanism strength test .

  14. 支柱绝缘子及瓷套超声波探伤工艺方法研究

    Research on Ultrasonic Inspection Technique of Pillar Insulators and Porcelain Cover

  15. PSL-12/4防雷支柱绝缘子在配电线路上的应用

    Application of PSL-12 / 4 lightning-proof post insulators to distribution lines

  16. 带普通外圆导柱的丝锥户外针式支柱绝缘子

    Tap with plain cylindrical pilot outdoor pedestal type post insulator

  17. 清洁的支柱绝缘子在酸性降水环境中的交流闪络特性

    AC Flashover Characteristics of Clean Post Insulators Under Acid Rain

  18. 安装不当导致支柱绝缘子断裂的原因分析

    Analysis of the Reasons for Post Insulator Fault Resulting from Improper Installation

  19. 高压直流支柱绝缘子电化学腐蚀试验研究

    Study and Test of Electrolytic Corrosion for HVDC Support Insulator

  20. 倾斜和缩进式转向管柱户外针式支柱绝缘子

    Tilt and telescopic steering colum outdoor pedestal type post insulator

  21. 光滑支柱绝缘子覆冰直流放电特性试验研究

    DC Discharge Performance of Cylindrical Post Insulators Covered with Ice

  22. 高压瓷支柱绝缘子防止断裂技术的研究

    The Research on High Voltage Porcelain Post Insulators Crack

  23. 复合支柱绝缘子直流污闪与污雨闪性能的比较

    DC pollution flashover and rain performance for composite post insulators at high altitudes

  24. 实芯棒形支柱绝缘子运行性状的试验与分析

    Test and Analysis On Operating Characteristics of Solid Bar Shape 's Pillar Insulator

  25. 支柱绝缘子污秽闪络机理分析

    Analysis of Flashover Mechanism of Polluted Post Insulators

  26. 大型空心并联电抗器支柱绝缘子抗震性能分析计算

    Calculation and Analysis of Aseismic Performances of Supporting Insulators in Large Shunt Air-Core Reactor

  27. 摘要介绍了一种新型带电清扫变电站支柱绝缘子的机器人。

    A new robot for hot-line sweeping of post insulators in substations is introduced .

  28. 高强度环氧树脂浇注式支柱绝缘子的研制

    Research on high strength support epoxy insulator

  29. 在高海拔、淋雨、污秽环境中电站型支柱绝缘子的直流放电特性

    DC Discharge Characteristics of Substation Support Insulators in High Altitude , Rain and Pollution Environment

  30. 降低隔离开关支柱绝缘子断裂危害的倒闸操作方案分析

    Analysis of Operation of Change-over Switch Scheme to Reduce Rupture Risk of Isolating Switch Post Insulator