量热计
- 网络Calorimeter;DSC;bolometer
-
一种PVC复合板燃烧性能的锥形量热计实验研究
Experimental Study of Flammability of PVC Composite Board by Means of Cone Calorimeter
-
使用锥形量热计、热重分析仪对聚乙烯(PE)/粘土纳米复合材料的燃烧性能进行了研究。
The flammability of PE / clay nano-composites has been studied by means of cone calorimeter and TG .
-
报道了一台硅吸收剂量量热计的结构和特性,给出了用该量热计测量脉冲X射线辐射剂量的实验结果。
The structure and performance of a silicon absorbed dose calorimeter are reported . The experimental results for flash X-ray radiation doses are presented .
-
金属间化合物Nd3Co的比热测定最简单的量热计是一个带温度计的金属容器。
The Specific heat of intermetallic compounds Nd_3Co ; The simplest calorimeter is a metal vessel used with a thermometer .
-
我有T1下的反应物和量热计。
I 've got reactants and calorimeter at T1 .
-
采用加压示差扫描量热计法(PDSC)对大庆150SN及其吸附色谱分离所得15个镏分与加入不同量的各种添加剂后的热氧化安定性进行了研究。
The pressure differential scanning calorimetry ( PDSC ) was used to study the thermal-oxidation stability of Daqing150SN and its15 fractions obtained by chromatographic separation .
-
本文用差示扫描量热计(DSC)研究了天然橡胶(NR)与顺丁橡胶(BR)并用硫化胶的耐热氧稳定性。
Influence of ingredients on thermal oxidative stabilities of NR / BR vulcanizates were studied by DSC .
-
利用差动扫描量热计(DSC)、偏光显微镜、X射线衍射等手段对该共聚酯进行了表征。
The liquid crystalline properties and other properties were elementarily studied by polarized microscope a hot stage , wide angle X-ray diffraction and differential scanning calorimetry .
-
利用差热扫描量热计(DSC)、红外光谱仪(FTIR)、扫描电镜(SEM)和力学性能测试等手段研究了PMMA/PVC二元共混体系的形态结构和性能。
The morphological structures and properties of the PMMA / PVC binary blends were studied by DSC , FTIR , SEM and mechanical test .
-
方法:本研究检索了4个主要数据库:Medline(1966-2000);镭基准监测量热计
Method : We searched Medline ; The Microcalorimeter for Radium Primary Standard
-
同时利用差式扫描量热计(DSC)记录加和不加5%DMSO的血小板在降温过程中的放热峰。
The heat release graphs of platelets cryopreserved with or without 5 % DMSO were also measured by differential scanning calorimeter ( DSC ) .
-
通过示差扫描量热计(DSC)分析证明,片状银粉表面能量大小与粉末的物理状态有关。
By means of DSC , the results of investigation showed that the level of surface energy of flaked Ag powder was correlated with physical state .
-
本文用偏光显微镜和示差扫描量热计(DSC)方法研究了碛纤维对聚丙烯结晶行为的影响。
Polarizing microscopy and differential scanning calorimetry ( DSC ) were used to study the effect of carbon fiber on the crystallization of polypropylene ( PP ) .
-
为验证量热计的准确度,选用标准物质TiO2进行测定,实验15次,相对偏差为0.98%。
The standard substance TiO2 was selected to verify the accuracy of the calorimeter . 15 runs were conducted , with an average deviation of 0.98 % .
-
采用示差扫描量热计(DSC)和X射线衍射方法研究了Ni(82.5)Cr7Si(4.5)B3Fe3多元非晶态合金钎料在加热时的晶化特性。
The crystallization behavior of polyatomic amorphous alloy Ni_ ( 82.5 ) Cr_7Si_ ( 4.5 ) B_3Fe_3 in heating is studied by means of differential scanning calorimeter ( DSC ) and X-Ray diffraction techniques .
-
用差动扫描量热计(DSC)研究了一种有机磷酸盐类成核剂(A)、山梨醇类成核剂(D)成核PP和纯PP的等温结晶行为和熔融特性。
The isothermal crystallization behavior and melting characteristics of polypropylene ( PP ) nucleated by a phosphate nucleating agent ( A ) and a sorbital nucleating agent ( D ) were studied by differential scanning calorimetry .
-
美国国家标准局(NBS)主要从事激光功率和能量测量用的电校准量热计的设计和研制。
NBS ( U. S. National Bureau of Standards ) maintains a set of electrically calibrated calorimeters designed and built specifically for laser energy measurement .
-
量热计测定结果表明,不同地区银杏(Ginkgobiloba)叶热值(caloriccontent,亦称等容燃烧热,Qv)不同,显示地域性条件对银杏叶能态具有较大影响。
It is proved by determination of caloric meter that ginkgo leaves from different areas vary on their caloric content , which shows that local condition can affect greatly on the leaves ' energy state .
-
用于400~1700K焓测量的自动绝热铜块量热计
An Automatic Adiabatic Copper-block Drop Calorimeter for Enthalpy Measurements in the Range 400 to 1700K
-
用差热扫描量热计(DSC)分析仪测定了BOPP主料、辅料的熔点及降温结晶行为,定性分析了辅料的组成,探讨了测试结果在BOPP生产线上的应用。
By DSC , melting points and temperature decline crystalline behaviours of BOPP principal and auxiliary materials were measured . The compositions of auxiliary materials were analyzed qualitatively , and the application of the testing results in BOPP production was discussed .
-
用差示扫描量热计(DSC)测定5个汽油馏分(沸点小于200℃)在243~299K范围内的比热容,测量误差在±2%以内。
Specific heat capacities of 5 gasoline fractions were measured at temperatures from 243K to 299K by a differential scanning calorimeter ( DSC ) with an average deviation less than ± 2 % .
-
利用WZR-1A型精密微电脑量热计系统地测量了食用大豆油的恒容燃烧热。
The heat values under constant volume ( Qv ) of edible soya oil were measured with WZR-1A microcomputer calorimetry .
-
对PMMA和松木两种典型的固体可燃物,采用基于耗氧原理的燃烧热释放速率测量方法,利用锥型量热计系统,在不同外加辐射热作用下测量了热释放率。
In this paper PMMA and pine are chosen as two typical solid materials . The method based on the principle of oxygen consumption is applied , the Calorimetry System is used , and the heat release rates of solid combustion with different fluxes radiant heat are measured .
-
着重叙述量热计与等温夹套之间热交换的计算以及从试样终温校正到298.15K的方法,根据实验数据给出校正方程式。
This paper describes mainly the calculation of the heat exchange between the calorimeter and the isothermal jacket , and the method for correcting the final sample temperature to 298.15K , giving a correction equation based on experimental data .
-
性能测试表明:钚量热计的样品热功率测量下限为4mW、测量上限高于9W,灵敏度约为202mV·W~(-1),线性范围为4mW~9W。
The performance tests show that the sensitivity of calorimeter is about 202 mV · W-1 and the linear scope of the measuring thermal power is from 4 mW to 9 W. The thermal power of plutonium was measured by the calorimeter .
-
基于物质间相互作用时存在的热能效应,几年来,本文用MS-80标准型Calvet微量量热计进行了一系列药物与人体细胞某些生物大分子相互作用的热动力学实验。
According to the heating effect caused by interaction between matters , a series of experiments on the interaction between drugs and cells from human bodies , DNA and physiological saline have been carried out with a MS-80 standard Calvet microcalorimeter .
-
木材的燃烧性能研究&锥形量热计法
Study on the combustion performance of the timbers - CONE calorimeter
-
量热计数据采集和处理系统的设计
Design of a Data Acquisition and Processing System Used for Calorimeter
-
转动弹燃烧量热计与噻蒽燃烧热的测定
A precision ROTATING-BOMB calorimeter and the heat of combustion of thianthrene
-
提高平衡环境型房间量热计制冷量测试精度的探讨
Improvements on Accuracy in Measuring Cooling Capacity with Typical Ambient Calorimeter