灭菌器

miè jūn qì
  • sterilizer
灭菌器灭菌器
  1. PLC和触摸屏控制系统在灭菌器上的应用

    The Application of PLC and Touch Screen Control System in Sterilizer

  2. 目的探讨B级脉动真空压力蒸汽台式灭菌器对牙科手机的灭菌效果。

    Objective Discuss sterilization effect of B-class pulsation table top vacuum pressure steam sterilizer for dental handpiece .

  3. 基于PLC的脉动真空蒸汽灭菌器

    The pulse vacuum vapor sterilization machine based on PLC

  4. 基于CPLD的脉动真空灭菌器控制系统开发

    Development of Control System of Pulsant Vacuum Sterilizer Based on CPLD

  5. 介绍触摸屏和PLC在脉动真空灭菌器控制系统中的应用研究。

    This paper introduces the application study of touching screen and PLC in control system of the pulsant vacuum sterilizer .

  6. 高压蒸汽灭菌器是GMP认证过程中要求验证的设备。

    High-pressure steam sterilizer is the equipment required to be verified in GMP authentication .

  7. 美国AmscoCentury型蒸汽灭菌器压力和温度的校准

    Calibrating temperature and pressure of Amsco Century steam sterilizer

  8. GMP认证中对高压蒸汽灭菌器的验证高温高压过热蒸汽处理木材的热稳定性

    Validation of Autoclaves for GMP Certification Thermal Stability of Superheated Steam-treated Wood under High Temperature and Pressure

  9. 本文论述了机动门脉动真空灭菌器在使用中的科学化管理,质量保证(QA)与质量控制(QC)及预防性维修。

    DWE in use , it is not only include QA and QC but also the prevention maintains .

  10. 主要介绍了以研华产品的IC、IA系列产品为主研制的环氧乙烷灭菌器计算机监控系统。

    The computer monitor system of ethylene oxide sterilizer , whose core is YANHUA 's IC and IA serial products , is mainly introduced in the text .

  11. 真空灭菌器B-D试验效果监测分析

    B-D Test for Vacuum Sterilizer : A Monitoring Analysis

  12. 浅谈脉动真空灭菌器B-D试验

    Talking About B-D Test of Pulsation Vacuum Sterilizer

  13. 通过脉动预真空压力蒸汽灭菌器B-D试验监测,分析并找出影响B-D试验结果的不合格因素。

    This paper analyzes the disqualification factors influencing B-D test results by using B-D test monitoring .

  14. 分析了新华XG1。PG型真空灭菌器的一例故障现象、故障原因及排除方法。

    Analyzes mainly a case of troubleshooting for Xin Hua XG1.PG Vacuum Sterilizer , and tries to find the causes of it and then search for solution ways .

  15. 本文通过对B-D试验的阳性检测结果进行较系统的验证,分析其阳性检测结果产生的原因,避免因误判而影响灭菌器的正常使用。

    In this paper , we verify the masculine result and analyze the cause in order to avoid normal usage of sterilization machine .

  16. 设计了脉动真空灭菌器控制系统以及利用GPRS模块远程监控温度压力信号模块,阐述了硬件方面的安全性能和抵抗外界干扰因素的能力。

    This paper introduces the design of temperature and pressure monitoring module and remote monitoring the temperature and pressure signal of the GPRS module , introduces the hardware aspects of safety performance and resistance to external interference factors of ability .

  17. DMQ-0.3多功能灭菌器不能自动脉动真空的故障检修

    Elimination of the fault of non-autopulse vacuum of DMQ-0.3 multifunctional sterilizer

  18. 在监测灭菌器内室冷空气排除效果中,探索一种优于B-D试验的检测方法。

    In order to monitor the effect of exhausting cold air through sterilizer , we propose a vacuum test method in ˉ stead of B-D test .

  19. 樱花NSS-O系列高温灭菌器常见故障排除与维护

    Troubleshooting and Maintenance of Sakura NSS-O High-temperature Sterilizer

  20. 结论用来检测压力蒸汽灭菌器灭菌效果方法之一的3M压力蒸汽灭菌包内化学指示卡变色不标准因素,受蒸汽灭菌过程中蒸汽的冷凝水的影响;

    Conclusion The discoloration of chemical indicative cards of 3 M-pressure steam sterilizer is one of measures to detect the effect of pressure steam sterilizer ; its nonstandard discoloration is influenced by condensed water of steam during the steam sterilization .

  21. 本文对LMQ.R-4060立式灭菌器应用于粉针车间化验室的营养琼脂培养基及肉汤培养基的灭菌进行探讨。结果显示,LMQ。

    The LMQ , R-4060 upright-sterilization-vessel which sterilize the nutrition agar medium and broth medium in the laboratory of powder-noodle plant is the ideal sterilization apparatus .

  22. 由于外加强带圆角矩形截面灭菌器结构特殊,GB150-1998中规定的应力公式不能适用,需运用数值方法对其进行强度计算和校核。

    Due to its special structure , design of strengthening rectangular sterilizer with circular corner cannot use the stress formula given in the standard GB150-1998 .

  23. 结论,医用快速灭菌器对少量骨科器械在灭菌温度210~250℃维持灭菌8min,可达到灭菌要求。

    Conclusion : The Medical Quick Sterilizer can fulfil sterilization requirement for small quantity of orthopedic instruments at sterilizing temperature 210 ~ 250 ℃ maintained for 8 min.

  24. 结果,液体石蜡油和凡士林油膏经650W微波灭菌器照射20min和25min,可全部杀灭嗜热脂肪杆菌芽孢;分别照射25min和30min,可全部杀灭枯草杆菌黑色变种芽孢。

    The results showed that 650 W microwave sterilizer irradiation to liquid paraffin and vaseline ointment for 20 min and 25 min could kill all spores of Bacillus stearothermophilus and irradiation for 25 min and 30 min could kill all spores of Bacillus subtilis var. niger .

  25. 实验室测试证明,使用DMQ型多功能灭菌器进行脉动真空压力蒸汽灭菌(脉动3次,温度132℃)作用4分钟;

    Laboratory experiment showed that excellent result in sterilization of ordinary medical supplies pack was obtained with any of the following sterilization methods using multi-func - tional autoclave Type DMQ : pulsating prevacuum autoclaving ( air exhaustion for 3 times , temperature 132 ℃) for 4min ;

  26. 真空灭菌器内室冷空气排除效果监测的研究

    The research of monitoring cold air exhaust ben the vacuum sterilizer

  27. 三次预真空灭菌器控制系统的研发

    The Controlling System of the Triple Pulse Vacuum Sterilizer in Dentistry

  28. 我院脉动真空灭菌器灭菌质量的监测

    Monitoring of sterilization quality of pulsating vacuum sterilizer in our hospital

  29. 脉动真空灭菌器在实验动物屏障设施中的使用体会

    Application of Pulsating Vacuum Sterilizer in Barrier Facilities of Laboratory Animals

  30. 预真空高压蒸汽灭菌器脉冲灭菌法的研究

    Study on sterilization by pulsing treatment with high - vacuum autoclave