气体绝缘开关设备
- 网络GIs;Gas Insulated Switchgear
-
40.5kV封闭式气体绝缘开关设备就地微机保护与状态监测装置
On-site microprocessor protection & condition monitor device of 40.5 kV gas insulated switchgear
-
介绍了一种用于40.5kV封闭式气体绝缘开关设备的就地微机保护与状态监测装置的功能、软硬件设计及调试情况。
This paper introduces the function , design and debugging of a on site microprocessor protection and condition monitor device of 40.5 kV gas insulated switchgear .
-
气体绝缘开关设备中局部放电的在线监测技术
On line partial discharge monitoring techniques for gas insulated substations
-
六氟化硫气体绝缘开关设备装配质量控制
Assembly Quality Control on Sulphur Hexafluoride Insulated Switchgear
-
气体绝缘金属封闭开关设备(GIS)安装的质量控制
Quality Control for Installation of GIS
-
超高频(UHF)局部放电在线监控系统可预防气体绝缘金属封闭开关设备(GIS)发生灾难性故障。
The UHF partial discharge online monitoring system can prevent the disastrous fault for GIS .
-
在应用气体绝缘全封闭开关设备(GIS)的变电站设计中,要充分考虑GIS的结构特点。
In the substation design with gas insulated switchgear ( GIS ), the structure features of GIS should be taken into the consideration .
-
气体绝缘金属封闭开关设备(gasinsulatedswitchgear-GIS)也称作气体绝缘变电站(GasInsulatedSubstation-GIS),以其结构紧凑、运行可靠、易于维护等优点而在电力系统中得到广泛应用。
GIS ( Gas Insulated Switchgear or Gas Insulated Substation ) has been widely used in electrical power system because of its advantages such as compact structure , reliable operation and easy maintenance .
-
介绍变电站新老气体绝缘金属封闭开关设备(GIS)的对接工作流程以及在设计过程中母线对接的设计、工艺方案和要点。
Introduction to the interface flow chart of interconnection of newly-developed gas insulated metal-enclosed switchgear ( GIS ) to existing gas insulated metal-enclosed switchgear ( GIS ), and design , manufacturing process scheme and key points on such interconnection of busbars .
-
文章对一起110kVSF6气体绝缘金属封闭开关设备(GIS)母线分支气室SF6气体微渗事故的缺陷检查、处理过程以及事故原因进行了介绍分析。
The defect inspection , handling process and the causes of SF_6 micro-leakage fault of bus branch air chamber for 110 kV SF_6 GIS metal enclosed switchgear were introduced .
-
分析了高压SF6全封闭组合电器(气体绝缘开关GIS)设备安装过程中应注意的若干技术问题,叙述了安装的工艺流程、技术条件、要求等。
The technical problems in installation of high voltage SF6 full sealing combination electric appliance ( gas insulating switch GIS ) are analyzed , and the technological process , technical conditions and technical requirements in installation are described .
-
介绍了SF6气体绝缘金属封闭开关设备发生内部故障电弧的危害,分析了发生故障时电弧使壳体烧穿及气压升高使壳体爆裂的产生机理,从而提出了在设计上应采取的措施。
This paper introduces the dangers caused by internal fault arc in GIS and discusses the mechanism of metal tank burning through and exploding , then proposes the improvement in design .
-
1000kV高性能气体绝缘金属封闭开关设备(GIS)是1000kV交流输电系统不可或缺的元件。
The 1000 kV Gas Insulation Switchgear ( GIS ) with high performances is the important element of 1000 kV AC power transmission system .
-
GB7674-199772.5kV及以上气体绝缘金属封闭开关设备
Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
-
中压SF6气体绝缘交流金属封闭开关设备设计
Medium-voltage SF_6 Gas Insulated AC Metal Closed Switchgear Design
-
为减少气体绝缘金属封闭式开关设备(GIS)产品运行期间的成本,必须改变维护方式,即从设备的定期维护改变到状态维护。
To reduce the cost during operation for gas insulated and metal enclosed switchgear ( GIS ), it must be changed for the maintenance way from periodic to condition - based .