血气分析仪

  • 网络blood gas analyzer;CO-oximeter;Abbott i-STAT System
血气分析仪血气分析仪
  1. 由血气分析仪(BAYER型号:248)测定动脉血气。

    The partial pressure of oxygen was measured with blood gas analyzer ( BAYER 248 ) .

  2. 文采用最小二乘法求取回归方程,从而校正血气分析仪PCO2测定系数的误差。

    This article finds out regression equation by using least square method , in order to rectify coefficients'errors in measuring PCO2 by pH / blood gas analyzer .

  3. 血气分析仪精密测定泪液pH值

    Gas Analyses Precise Determination of Tear pH by Automatic Blood Gas System

  4. GEMPremier3000血气分析仪常见故障及解决方法

    Methods and common trouble of Gem premier 3000 clinical analyzer

  5. 目的:评价AVLcompactⅢ型血气分析仪的基本性能。

    Objective : To evaluate the basic performance of AVL compact ⅲ type blood - gas apparatus .

  6. 使用AVL血气分析仪进行质量控制的探讨

    How to Control the Quality of AVL Blood Gas Analysis Instrument

  7. 罗氏OMNI系列血气分析仪电极的修复

    Fixing the electrodes of Roche OMNI blood gas analyzers

  8. 采用放射免疫分析法、血气分析仪、肺功能仪分别测定20例肺纤维化患者和20例正常人血清PC、C和HA含量及血气、肺功能参数。

    The blood levels of PC ⅲ, CIV and HA in 20 patients with pulmonary fibrosis and 20 normal subjects were measured by radioimmunoassay and were analysed in relation with the artery blood gas and pulmonary function parameters .

  9. NOVAM7血气分析仪代谢电极故障排除与测定结果的影响因素

    Trouble shooting and factors effecting the text outcome for the metabolite electrodes in NOVA M7 blood gas analysis machine

  10. 为探讨常见新生儿黄疸中碳氧血红蛋白(COHb)检测的临床价值,以德国800系列生化血气分析仪附加的270-血氧仪检测动脉化毛细血管血COHb,同步取静脉血检测血清总胆红素(STB)。

    To evaluate the clinical value of the level of carboxyhemoglobin ( COHb ) in neonatal jaundice .

  11. i-STAT血气分析仪的维护

    Maintenance of i-STAT blood gas analyzer

  12. 结果:AVLcompactⅢ血气分析仪测定PH、PCO2和PO2的精密度高,批间变异系数分别为021、316、617;

    Results : PH ? PCO2 and PO2 measured by AVL compact ⅲ type blood-gas apparatus got high precision and accuracy , the coefficients of variation of reproductive test were 0.21 ? 3 16 and 6 17 respectively .

  13. 本文介绍ABL50型血气分析仪使用过程中遇到的电、液路故障处理方法。

    The paper describes the ways to maintain the circuit and the fluid pipe of ABL50 blood gas system .

  14. 用经皮血气分析仪测量3组皮瓣的PO2和PCO2,2周后比较3组皮瓣成活率。

    Group ⅲ: without superficial venous trunks Instrument of transcutaneous blood gas analysis was used to measure PO 2 and PCO 2.Survival ratio of flaps were compared on 2 weeks postoperatively Results : PO 2 ?

  15. 方法:应用血气分析仪检测塑料和玻璃注射器冷藏全血标本PO2。结果:塑料注射器内全血贮存标本PO2随贮存时间延长而升高,而玻璃注射器则变化较小。

    Methods : Blood gas analyzer was used to measure PO 2 . Results : When whole blood was stored in plastic syringes , PO 2 tended to increase while in glass syringes , it had little change .

  16. 关于血气分析仪计量检定和质控问题

    The measurement and quality control of the blood gas analyzer

  17. 两台同一型号血气分析仪检测结果比较

    Comparison of the test results of two same type blood gas analyzers

  18. AVL&990血气分析仪缓冲液应用研究

    The Using Studies of AvI - 990 Blood - Gas Analysis Apparatus Buffer

  19. 血气分析仪标准溶液定值器的研制

    Development of Standard Solution Calibrator for Blood Gas Analyzer

  20. 血气分析仪结构原理及其进展

    Structure principle of blood gas analyzer and its progress

  21. 血气分析仪使用情况分析

    Analysis of the utilization of the blood gas analyzer

  22. 用血气分析仪检测患者白天动脉血气分析;

    The patients examined by Color Doppler Flow Imaging and arterial blood gas analysis .

  23. 血气分析仪与生化仪测定钾、钠离子的比较等离子体振荡分析仪

    Preliminary analysis of the potassium and sodium determined by blood gas analysis and biochemistry method

  24. 对血气分析仪检测通道、检测项目及操作方法进行探讨。

    This paper discussed testing channels 、 testing item and operation means about clinic analyzer .

  25. 血气分析仪检测方法探讨

    Discuss on testing means of clinic analyzer

  26. 采用血气分析仪分析细胞培养液气体含量,确定细胞处于低氧状态。

    ( 2 ) Analyze the cell culture fluid by blood-gas analyzer to ensure the deoxygenated culture .

  27. 文章的最后简单阐述了本人对未来血气分析仪技术的一种憧憬。

    And at the last of the article I look forward to the beautiful future of Blood gas analyzer .

  28. 血气分析仪是医院中不可缺少的临床检验设备之一,对临床医生具有重要的指导意义。

    Blood gas analysis machine , which can give the clinical doctor the important guidance , is one of the most important clinical test equipment .

  29. 自动血气分析仪检测换血前中后血常规、血气、电解质、血糖,计量资料用t检验对比分析。

    Blood routine , blood gas analysis , blood sugar was taken before , during and after the transfusion and the data obtained were analyzed using t test .

  30. 方法:从仪器的精密度,准确度,携带污染率来评价仪器,并将其与ABL330型血气分析仪作临床标本比较试验。

    Methods : The apparatus was evaluated from the precision ? accuracy and contamination , which was compared with ABL 330 type blood-gas apparatus for detecting clinical specimens .