彩色多普勒超声诊断仪

彩色多普勒超声诊断仪彩色多普勒超声诊断仪
  1. 方法用荧光免疫法测定血浆BNP水平,用心脏彩色多普勒超声诊断仪测定左室功能以及肱动脉血流调节的扩血管反应(FMD)。

    Methods BNP levels were measured by immunofluorescence assay . Color doppler echocardiography was performed to measure the left ventricular function and FMD .

  2. 方法:采用免疫荧光法测定63例心力衰竭患者和30例对照组血浆BNP浓度,用心脏彩色多普勒超声诊断仪测定并比较各组左室射血分数(LVEF)。

    Methods : A total of 63 patients with HF and 30 control subjects were investigated by measuring the serum BNP levels and the left ventricular ejection fraction ( LVEF ) .

  3. 所有病人行颈动脉超声检测,由专人操作,检测仪器为HP5500型彩色多普勒超声诊断仪,使用血管超宽频探头,频率为7.5MHz。

    All patients were observed by Color Doppler ultrasonography .

  4. 仪器:HP-500和HP-5500型(探头频率2~4MHz)彩色多普勒超声诊断仪。

    HP-500 and HP-5500 color Doppler echocardiography was used .

  5. 治疗前后用同位素放免法和放免法测定血浆心房钠尿肽、脑钠尿肽(ANP、BNP)水平,心脏彩色多普勒超声诊断仪测量左室结构和心功能;

    Plasma levels of atrial and brain natriuretic peptides ( ANP , BNP ) were measured by radioimmunoassay and immunoradiometric assay in these patients before and after treatment . Doppler echocardiography was performed to evaluate left ventricular function and structure .

  6. 方法使用Sequoia256、HP5500、ATL超9彩色多普勒超声诊断仪检查42例(44个人工瓣)术后重复出现临床症状的病人,并与手术结果进行比较。

    Methods 42 patients ( 44 prosthetic valve ) with post-operative symtoms were examined by using color Doppler ultrasound . The results were compared with surgical findings .

  7. 仪器设备:荷兰菲利蒲SONOS-5500型彩色多普勒超声诊断仪,周围血管高频探头频率4~10MHz。

    Instrument : Dutch Philips SONOS-5500 color Doppler ultrasound diagnostic apparatus , and the frequency of high-frequency detector in peripheral vessels was 4-10 MHz .

  8. 方法:应用ATL超9型APOOGE-800型彩色多普勒超声诊断仪,探头频率5.0~10.0MHz。对26例正常眼,36例轻中度近视眼,51例高度近视眼后巩膜进行观察。

    Methods : Morphology of rear sclera in 26 cases of normal control ( NC ), 36 cases of light and medium myopia ( LAMM ) and 51 cases of high myopia ( HM ) were observed by color Doppler ultrasound .

  9. 方法:用ASU-DIC型彩色多普勒超声诊断仪观察测定给药前后家猫心功能。

    Method : Observe and test the heart functions of normal domestic cats before and after the medicine ASU-DIC colorful dipolar ultrasonic diagnosis Set .

  10. 方法采用美国HP5500及飞凡彩色多普勒超声诊断仪,观察166例老年退行性心脏瓣膜病患者的心脏结构及心功能变化。

    Methods The cardiac structure and functional changes of the 166 cases of senile degenerative heart valvular diseases were studed with HP5500 ( USA ) and En Visor color doppler ( Philips ) .

  11. 利用HP-1000型彩色多普勒超声诊断仪和LING-100血液比黏度计分别观察其治疗前后血液流变学8项指标、患侧椎动脉血流量、血流管径和平均血流速度的变化。

    The eight indexes of hemorheology , flow volume of vertebral artery on the broken side , inside diameter of vein and average bloodstream velocity were observed with HP-1000 color doppler ultrasonic diagnosis apparatus and LING-100 blood viscosity meter .

  12. 材料与方法:用彩色多普勒超声诊断仪检查所有室间隔缺损病人,发现5例病人有残余瘘,并对病人进行跟踪观察。

    Materials and methods : Continuously observing the 5 cases of residual fistula after closure of VSD .

  13. 目的:了解彩色多普勒超声诊断仪在肢体电击伤血管损伤中的诊断价值。

    Objective : To evaluate the application of color Doppler ultrasonic diagnostic apparatus in the diagnosis of electric injury .

  14. 方法使用ATL-HDI5000彩色多普勒超声诊断仪对48例住院患者行超声检测。

    Methods 48 inpatients in the oral surgery of our hospital were observed with ATL-HDI 5000 color doppler ultrasound scanner .

  15. 彩色多普勒超声诊断仪在高压电击伤血管损伤诊断中的应用

    The Application of Color Doppler Ultrasonic Diagnostic Apparatus in the Diagnosis of Blood Vessel Injury due to High Voltage Electric Burn

  16. 主要探讨颈内动脉、椎动脉颅外段硬化性病变及血流动力学情况与梗塞灶的关系。使用高分辨力彩色多普勒超声诊断仪检测颈部颈动脉。

    The relation between cervical carotid atherosclerosis , hemodynamics and hemispheric infarct lesion was analyzed with high resolution color Doppler ultrasound .

  17. 治疗前后用彩色多普勒超声诊断仪检测肺血流动力学指标并作血气分析。

    Blood gases were analyzed and parameters of pulmonary hemodynamics were determined by color doppler supersonic diagnostic set before and after treatment .

  18. 方法首先使用彩色多普勒超声诊断仪确定病变的部位、大小、相邻关系,避开大的血管及重要的组织结构选择进针方向,然后消毒、局部麻醉。

    Methods Firstly , using color Doppler ultrasonic diagnostic apparatus to determine the locus , size of the focuses and their adjacent relations ;

  19. 方法动脉造影术所致股动脉假性动脉瘤11例,男性9例,女性2例。在Acuson128XP/10彩色多普勒超声诊断仪引导下行压迫修复。

    Methods Eleven patients with postangiographic femoral artery pseudoaneurysms , 9 male and 2 female , underwent compression repair with duplex and color Doppler ultrasound .

  20. 目的探讨不同彩色多普勒超声诊断仪对流速测定的可能影响,以及不同仪器测定流速与实际流速的差异和相关性。

    Objective To evaluate the probable effects of different instrumentation in velocity measurements and the correlations between the actual flow velocities and the Doppler flow velocity .

  21. 在敦化地区我院最早引进彩色多普勒超声诊断仪,也是本地区唯一可对先天性心脏病进行明确诊断的医院。

    Beginning the first hospital in the region to introduce color Doppler ultrasonic diagnostic apparatus , only in the region but also for the diagnosis of congenital heart disease in the hospital .

  22. 医疗设备行业是许多发达国家重点发展的高新技术行业,而彩超(彩色多普勒超声诊断仪)是这个行业中最有份量的产品之一。

    Medical equipment industry is a high-tech industry and many developed countries have put significant amount of efforts into . Color Doppler ultrasonic diagnosis system is one of the most important products in this industry .

  23. 方法:采用ALTULTRAMARK9型彩色多普勒超声诊断仪于电击伤肢体切开减张前后作彩色多普勒检查,观察血管直径、血管壁、血管内膜、血管内容物和血流速度等变化。

    Method : Altultramark type 9 color Doppler ultrasonic diagnostic apparatus was used to observe the changes in blood vessel diameter , blood vessel wall , inner membrane , blood content and blood flow rate in electrically injured limbs post and prior to fasciotomy .